- Medical Monitors
- Accessories for Monitors
Medical Monitors, Accessories for Monitors
PORTABLE VITAL SIGNS MONITOR WITH 12.1' COLOUR TFT DISPLAY AND PRINTER 12.2 IN
Vital signs monitor with TFT 12.1" colour display and printer. Standard configuration: ECG, NIBP, SpO2.
Please find demonstration video below.
ECG:
- Lead type: 5-lead
- Input: RA, LA, RL, LL, V
- Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
- Accuracy: ± 1bmp or ± 1%, which is higher
- Protection: with voltage 4000VAC/50Hz in isolation against electrosurgery and defibrillation
- S-T detection
- Arrhythmia analysis
- Acoustic and visual alarms
Standard configuration:
- ECG, NIBP, SpO2
- TFT 12.1" colour display
- Suitable for adult, pediatric and neonatal patients
- Basic functions (ECG, NIBP, SpO2) in 1 unit
- Adjustable acoustic and visual alarms
NIBP:
- Method: oscillometry
- Operating modes: Manual / Automatic / STAT
- Measurement unit: mmHg / kPa selectable
- Measurement types: systolic, diastolic and mean
- Pressure protection
SpO2:
- Measuring range: 0 ~ 100%
- Accuracy: ± 2 digits (70% - 100%)
- Unspecified (0% - 69%)
Additional info:
- Lithium battery
- Working time: 120 min
- Charging cycles: 10000
- Charging time: 4-5 hours
- Dimensiones: 25.5 (h) x 31 x 14 cm.
INCLUDED ACCESSORIES:
- ECG cable (1 unit)
- Temperature probe (1 unit)
- ECG circular electrodes
- Cuffs:
- 1 adult
- 1 pediatric
- 1 neonatal
- 1 obese
- Cuff interconnection tube 3.0 m (1 unit)
- Probes:
- 1 adult
- 1 pediatric
- 1 neonatal
- Printer paper rolls (13 pieces)
- Battery included
- User's guide in Spanish / English
OPTIONAL ACCESSORIES:
- 550-SMA: adult pulse oximetry probe
- 550-SMP: pediatric pulse oximetry probe
- 550-SMA: neonatal pulse oximetry probe
- 5020ROLL-10-550: thermal paper roll for printer
- 550-BATT8000I: spare rechargeable battery.
- 550-CABLEECG: ECG cable for 550 monitors
MULTIPARAMETER VITAL SIGNS MONITOR 12.1 TFT SCREEN
Multiparameter vital signs monitor of 12.1”. It has a discrete and modern design that provides exceptional lightness and makes it really practical and user-friendly. Its function panel is intuitive and clear, which makes the monitoring work way easier and comfortable.
CHARACTERISTICS:
- Medical device: class IIb
- Protection against electric shock: class I equipment (internal supply)
- Application range: adult, paediatric, neonatal, medicine, surgery, operating rooms, ICU, CCU
- Screen: 12.1” colour LCD TFT display
- Default configuration: ECG, ST segment, NIBP, SpO2, PR, RESP, TEMP
TECHNICAL DATA:
- AC: 100 - 240 V , 50/60 Hz
- DC: built-in rechargeable battery, 11.1V 24 wh, 2 using hours, 5 minutes of use since the low battery alarms sounds
- Size: 310 × 150 × 275 mm
- Weight: 2.8 Kg
- Operating environment:
- Temperature: 0 – 40 ºC
- Humidity: 15% ~ 80%
- Pressure: 86.0 kPa - 106.0 kPa
DATA STORING:
- Tendency diagram: 720 h
- NIBP analysis: 10,000 events
- Wave analysis: 12 h
- Alarm analysis: 200 alarm events
- Volumetric analysis of drug concentration
ECG
- 5 leads: RA, LA, LL, RL, V
- Lead mode: I, II, III, AVR, AVL, AVF, V
- Gain: x 1.25 mm/mV, 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV (error <- 5 %)
- Scanning speed: 6.25 mm/s, 12.5 mm/s, 25mm/s, 50 mm/s (error <- +- 10%)
- Bandwidth:
- Surgery: 1 - 25 Hz
- Monitor: 0.5 - 40 Hz
- Diagnosis: 0.05 - 130 Hz
- Sensitivity: > >200 u V P-P
- CMRR: > 112dB
- Input impedance: > 5M
- Calibration tension: 1 mV +- 5 %
ST SEGMENT
- Range: - 2.0 mV -+ 2.0 mV
- Precision: 0.02 mV
NIBP
- Method: oscillometry
- Measuring mode: manual, automatic, STAT
- Measurement range of automatic mode: 1-5/10/15/30/60/90/120/180/240/480 min
- Measurement range of STAT mode: 5 min
- Pulse range: 40 to 240 bpm
- Measurement and alarm range:
- Adult:
- Systolic: 40 – 280 mmHg
- Diastolic: 10 – 220 mmHg
- Arterial: 20 – 240 mmHg
- Paediatric:
- Systolic: 40 – 135 mmHg
- Diastolic: 10 – 160 mmHg
- Arterial: 20 – 170 mmHg
- Neonatal:
- Systolic: 40 – 135 mmHg
- Diastolic: 10 – 100 mmHg
- Arterial: 20 – 110 mmHg
- Measurement of static pressure:
- Range: 0 – 300 mmHg
- Precision: +- 3 mmHg
- Resolution: 1 mmHg
- Precision:
- Mas. arterial error: +- 5 mmHg
- Max. standard deviation: 8 mmHg
- Protection against electric overload:
- Adult: 300 mmHg
- Paediatric: 240 mmHg
- Neonatal: 150 mmHg
- Adult:
SPO2
- Measurement range: 0 – 100%
- Resolution: 1%
- Precision: 70% - 100% +- 2%/40% - 69% +- 3%
PULSE RANGE
- Range of alarm/measurement: 20 to 300 bpm
- Resolution: 1 bpm
- Precision: +- 3 bpm
RESP
- Impedance method between RA-LL
- Breathing impedance range: 0.3 – 3 ohm
- Base impedance range: 200 – 4000 ohm
- Bandwidth: 0.3 - 2.5 Hz
- Gain: x 2.5, x0,5, x1, x2, x4
- Breathing range:
- Measurement range:
- Adult: 0 - 120 rpm
- Neonatal/paediatric: 0 -150 rpm
- Measurement range:
- Resolution: 1 rpm
- Precision: 7 - 150 rpm (+- 2 rpm) / 0 - 6 rpm (non specified)
TEMP
- Channels: 2
- Alarm and measurement range: 0 – 50 ºC
- Resolution: 0.1ºC
- Precision (no sensor): +- 0.1 ºC (0 - 50 ºC)
INCLUDED ACCESSORIES:
- Tube and NIBP cuff
- Electrodes and ECG cable
- SpO2 sensor
- TEMP probe
- Built-in lithium battery
- Power cord
- User manual
PORTABLE MULTIPARAMETER MONITOR SPO2, PR, NIBP AND TEMPERATURE
Fast and simultaneous measurement of blood oxygen (SpO2), pulse rate (PR), non-invasive blood pressure (NIBP, cuff included) and temperature (probe included).
FEATURES:
- Up to 6,000 NIBP records (up to 100 patients. Each user can store 999 records).
- Measurement of the temperature by ear probe in 5 seconds.
- 4.3-inch LCD screen.
- Built-in lithium battery.
- Data transfer to PC, tablet or smartphone (compatible with IOS and Android 4.0 or higher) via USB or Bluetooth connection.
APPLICATIONS:
- First aid.
- Clinical examinations.
- Geriatric clinics.
- Home care.
- Primary care.
- Follow-up of patients.
ACCESSORIES INCLUDED:
- Transport bag.
- Lithium battery and charger.
- SpO2 adult probe.
- NIBP cuff for adults.
- Ear thermometer.
TECHNICAL SPECIFICATIONS:
SpO2:
- Measurement range: 35%-100%.
- Accuracy: +-2% for SpO2 75%-100% and +-3% for SpO2 50-74%.
Heart rate:
- Measurement range: 0-300 bpm.
- Accuracy: +-3%.
NIBP parameters:
- Measurement range: 0 mmHg-300 mmHg.
- Accuracy: +-3 mmHg.
- Measurement range: systolic pressure: 60 mmHg-240 mmHg; diastolic pressure: 30 mmHg-180 mmHg.
SPARE PARTS AND ACCESSORIES:
- 106-EARCOVER
8-INCH STANDARD VITAL SIGNS MONITOR
Vital signs monitor with a functional design and a great maneuverability thanks to its handle and its discrete button panel. Light and easy to transport wherever you need. Its 8-inch TFT LCD screen of bright colours provide excellent visibility.
STANDARD CONFIGURATION:
- SpO2, PR, NIBP, ECG, RESP, TEMP
- 8-inch colour TFT display
- Convenient for adults, and for paediatric and neonate patients
- Adjustable sound and visual alarms
ECG
- Lead selection:
- 3 derivations: RA, LA, LL (I, II, III)
- 5 leads: RA, LA, LL, RL, V (I, II, III, aVR, aVL, aVF, V)
- Heart rate range: 15 – 300 bpm
- Precision: ±1% or ±1 bpm
- Resolution: 1 bpm
- Pacemaker pulse inhibition:
- Amplitude: ±2 mV - ±700 mV
- Width: 0.1 ms – 2 ms
- Rise time: 10 us – 10 µs
- Sensitivity: > 200 uV
- Input impedance: > 5 µ ohm
RESP
- Range: 0 - 120 rpm
- Precision: ±2 rpm
- Resolution: 1 rpm
- Asphyxia alarm: 10 – 40 s
- Base impedance range: 200 – 400 ohm
- Impedance measuring range: 0.3 – 3ohm
- Bandwidth: 0.1 – 2.5 Hz
NIBP
- Method of measurement: oscillometry
- Operational mode: manual, automatic, STAT
- Measurement range of the automatic mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
- Measurement time of the STAT mode: 5 m
- Heart rate range: 40 – 240 rpm
- Systolic blood pressure range: 40 – 270 mmHg
- Diastolic blood pressure range: 10 – 215 mmHg
- Average pressure range: 20 – 235 mmHg
- Static pressure range: 0 – 300 mmHg
- Static pressure precision: ±3 mmHg
SPO2
- Range: 0 – 100%
- Resolution: 1%
- Precision:
- 70 – 100% : ±2 %
- 0 – 69%
- Pulse frequency range: 20 to 300 bpm
- Pulse frequency resolution: 1 bpm
- Pulse frequency precision: 3 bpm
TEMP
- Channel: 2
- Range: 0 – 50 ºC
- Resolution: 0.1ºC
- Precision: ± 0ºC plus the tolerance of the temperature sensor
WITH:
- Vital signs monitor
- Temperature probe
- Oximetry sensor
- ECG cable
- Cuff for adults
- Built-in battery
- User manual
- Power cord
VITAL SIGNS MONITOR WITH 15'' TFT DISPLAY, 3 LED STANDARD
Vital signs monitor with TFT 15" colour display, 3 LED and built-in printer.
- Standard configuration: ECG, RESPIRATION, NIBP, SpO2, TEMPERATURE,
- Additional configuration:
- IBP (ref. 550-9200IIBP / 550-9200IETCO2IBP)
- CO2 (ref. 550-9200IETCO2 / 550-9200IETCO2IBP)
STANDARD CONFIGURATION:
- 3 LED 15" TFT colour screen
- Printer
- Suitable for adult, pediatric and neonatal patients
- Basic functions (ECG, NIBP, SPO2) in one unit
- Adjustable audible and visual alarms
- ECG, RESPIRATION, NIBP, SPO2, TEMPERATURE
- CO2 (ref. 550-9200IETCO2 / 550-9200IETCO2IBP)
- IBP (ref. 550-9200IIBP / 550-9200IETCO2IBP)
ECG:
- Lead type: 5-lead
- Input: RA, LA, RL, LL, V
- Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bmp or ± 1%
- Arrhythmia analysis
- Tachycardia alarm
- Acoustic and visual alarm (alarm tests vested)
NIBP:
- Method: oscillometry
- Operating modes: Manual / Automatic / STAT
- Measurement unit: mmHg / kPa selectable
SPO2:
- Measuring range: 0 ~ 100%
- Resolution: 1 bpm
- Alarm range: 0-100%
- Update: approx. 1 s
STANDARD ACCESSORIES:
- ECG cable (1 unit)
- Temperature probe (1 unit)
- ECG circular electrodes
- Cuff: 1 adult / 1 pediatric / 1 neonatal / 1 obese
- Cuff interconnection tube 3.0 m (1 unit)
- Cuff tube 3 m (1 unit)
- Probe: 1 adult / 1 pediatric / 1 neonatal
- Battery included
ADDITIONAL INFO:
- Lithium battery
- Working time: 120 min
- Charging cycles: 10000
- Charging time: 4-5 hours
VETERINARY VITAL SIGNS MONITOR WITH CO2 CAPNOGRAPHY
Veterinary Vital Signs Monitor with ETCO2.
The vital signs monitor is intended for use in special procedures in laboratories or in a veterinary clinic where veterinary surveillance systems are needed.
FEATURES:
Heart / pulse rate: It measures with the parameters ECG, oximetry and noninvasive blood pressure (NIBP).
Electrocardiogram (ECG):
- The monitor provides the continuous process of 5 lead ECG, with standard derivation selection and filtering electrocautery discharge.
- You can display up to 3 channels of waveform simultaneously.
Oximetry: The oximetry parameter provides continuous noninvasive monitoring of oxygen saturation (% SpO2) in the arterial and pulse frequency (PR).
Noninvasive arterial pressure (NIBP):
- The noninvasive arterial pressure parameter (NIBP) provides values as systolic and diastolic blood pressure and average plus heart rate.
- NIBP measurements can be made automatically, manually or STAT.
Respiraty Rate (RR): The monitor provides respiratory rate and Resp wave form by measuring thoracic impedance between two ECG electrodes on the patient's chest.
Temperature (TEMP): Includes two independent temperature control channels (T1 and T2).
CO2:
- The monitor determins the concentration of CO2 in respiratory gases by measuring the amount of light absorbed by these gases.
- EtCO2 is displayed as a numeric value in millimeters of mercury (mmHg), percentage (%) or kilopascals (kPa).
- Furthermore, a CO2 waveform (capnography) can be viewed, a valuable clinical tool which may be used to assess the integrity of the patient´s airway and proper placement of the endotracheal tube.
- The respiratory frequency is calculated by measuring the time interval between the detected breaths.
Monitor:
- The monitor has a colour LCD screen with high resolution and high contrast.
- It provides a continuous, real-time image with up to 4 wave forms.
- It also shows the measured values, historical data, measurement trends, alarm limits and patient information.
Internal battery:
- The internal rechargeable battery is primarily intended for backup and switching use.
-
The expected life of the battery is 2-5 years, depending on its use.
-
A fully charged battery will last 2 to 3.5 hours depending on the usage of the monitor.
You can select patient type:
- Horse
- Dog
- Cat
TECHNICAL SPECIFICATIONS:
Display:
-
7 inches high resolution, active matrix flat screen (TFT: Thin Film Transistor).
- Resolution: 800 x 480 pixels.
Indicators:
- LED working status
- LED AC power
- LED battery charger
- LED battery supply
- LED alarm silence
Alarm volume: 45dBA to 85 dBA, at 1 metre distance (adjustable).
ECG:
-
Heart rate range: 20-350 lpm
-
Accuracy of heart rate: 2 lpm or ± 2% (whichever is greater)
-
QRS detection range: 0,5 to 5 mV
- Pacemaker pulse detection: Amplitude: 2 mV to 700 mV
- Detection length: 0,1 - 2,0
- Alarm heart rate ranges:
- High: 20-350 lpm and off
- Low: 20-350 lpm and off
- Average heart rate: 8 seconds fixed as average
- Lead selection: I, II, III, V, aVR, aVL, or aVF (5-lead)
- Gain display settings: X 1/4, X1/2, X1, X2, X4
- Input range: -5,0 mV to +5,0 mV
- Frequency response: 0,05 Hz to 40 Hz
- Input impedance: Differential > 5 Mohms, as required and tested by ANSI/AAMI EC-13.
- Leakage: < 10 uA
- Isolation of patients: > 4000 VCA
- Waveform display: 120 Hz; 6.25, 12.5, 25, or 50 mm/s
- Frequency digits update: 1 Hz
SpO2:
- SpO2 range: 0-100% functional saturation
- SpO2 accuracy:
- 70-100% ± 2%
- <70% unspecified
- Pulse frequency range: 20-350 lpm
- Pulse frequency accuracy: ± 2 lpm or ± 2% (whichever is greater)
- SpO2 alarm range:
- High: 50 - -100% and off
- Low: 50 - -100% and off
- Calibration: Factory calibrated SpO2 range of 50% to 100% using human blood samples to a functional saturation.
NIBP:
- Blood pressure measurement
- Measurement method: Oscillometric with reducing deflation
- Range: Systolic: 40 a 270 mmHg
- Blood average: 30 to 220 mmHg
- Diastolic: 20 to 200 mmHg
- Pulse: 25 to 300 lpm
- NIBP accuracy: Algorithm based on human algorithm that meets or exceeds the accuracy requirements of standards ANSI / AAMI SP10:1992 and 2002 for non-invasive blood pressure using the oscillometric method.
- Inflation pressure setting.
- Measurement time: 30 to 50 seconds (typical), 120 seconds maximum
- Inflation pressure preset:
- 200 mmHg - Cat
- 150 mmHg - Dog
- 120 mmHg - Horse
- Calibration: Factory calibrated
- AUTO time interval: 2, 3, 5, 10, or 30 minutes, or 1, 2 hours 20-260 (in steps of 1 mmHg), and off
- Alarm range: 25- 250 lpm, ± 2% or ± 3 lpm (whichever is greater)
- Pulse frequency accuracy: 251-300 lpm, ± 5%
Respiratory rate (RESP):
- Range: 0-120 breaths per minute (rpm)
- Accuracy: ±1 rpm
- Resolution: 1 rpm
- RESP alarm range:
- High: 0-120 rpm (1 rpm steps) and off
- Low: 0-120 rpm (1 rpm steps) and off
Temperature (TEMP):
- Channel: Two
- Range: 25-45ºC
- Accuracy: ± 0.2ºC plus tolerance of the temperature sensor
- Resolution: 0.1ºC
- TEMP alarm range:
- High: 35.5-43.5ºC and deactivated in 0.1 increments
- Low: 35.5-43.5ºC and deactivated in 0.1 increments
CO2:
- Sampling mode: Secondary
- Measurements parameters: Respiratory rate, EtCO2 and InsCO2.
- CO2 warm up time: 10 seconds.
- Measuring range:
- CO2: 0~150mmHg
- Respiratory rate: 2~150bpm
- Accuracy:
- 0~40mmHg ±2mmHg
- 41~150mmHg ±10% reading
- Resolution: 0.1mmHg
- Flow rate: 50 ml/min±10 ml/min
Power requirements: AC input: 100 to 240 V, 50/60 Hz
Dimensions:
- Width: 300 mm.
- Length: 180 mm.
- Height: 130 mm.
- Weight equipment: 2 kg approx.
- Weight total: 3.6 kg approx.
Environmental protection:
- Temperature:
- From 0 to 50 0C (operation)
- From -40 to 75 0C (storage)
- Humidity:
- From 15 to 95% (operation)
- From 10 to 95% (storage)
Equipment classification:
-
Protection type (againt electrocutions): CLASS I (internal power supply)
-
Operation mode: Continuous
- Degree of protection (against liquid ingress): IPX1, drip proof
- Degree of mobility: Portable
-
Degree of protection (against electrocutions): Type CF
- Safety requirements: EN60601-1:2002
INCLUDES:
- Veterinarian vital signs monitor
-
Extension cord SpO2 + 2 oximetry sensors
- Cable, ECG, 5-lead + 5 clamps
- NIBP tube with:
- NIBP cuff, large, 7-13 cm (horses)
- NIBP cuff, medium, 6-11 cm (dogs)
- NIBP cuff, small, 4-8 cm (cats)
- Rectal temperature probe
- Accessories for CO2
- Internal battery
- Power cable
- User manual
CERTIFICATION:
- Directive CE 93/42 on Medical Products.
STAND FOR VITAL SIGNS MONITORS
Description:
- Vital signs monitor supporting base MODEL 550-6000I
- Rotating base of 58 cm diameter (22,62 in)
- Height 100 cm aprox. (39 in)
- Basket inclued (16 x 23 x 16 cm / 6.3 x 8.97 x 6.3 in)
- Metalic frame and basket
- Weight: 10.2 kg / 22.5 lb
SPARE BATTERY FOR 550-6000I VITAL SIGNS MONITOR
Spare battery for vital signs monitor, model 550-6000I.
Cuff for monitors 9200I, 8000I, 6000I,
9200I, 8000I, 6000I Neonatal
9200I, 8000I, 6000I Adult
9200I, 8000I, 6000I Pediatric